< a href=" " rel="nofollow">Chat with us, powered by < a href="https://www.livechat.com/?welcome" rel="noopener nofollow" target="_blank">LiveChat

News

Home / News / How to Choose a Fire Pump Set
News

How to Choose a Fire Pump Set

If you're planning to install a fire pump system in your building, then you should first understand the importance of a good pump set. You should also consider the safety of your property and the people in it. Here are some tips that will help you choose a fire pump set. Read on to learn how you can purchase one for your building. Read on to learn about the different types of pump sets available. The next time you have a fire, you'll want to make sure you have the right one.
The is the minimum pressure that a fire pump set must be able to achieve at a particular point. It is vital that the Q-H curve is stable so that the pump will work properly. Otherwise, it may cause vibrations and even system breakdowns. The National Fire Protection Association's guidelines provide a good foundation for choosing the right pump set. They also outline the requirements for routine maintenance.
When selecting a fire pump set, it is vital to check the certifications that it has received. NFPA 20 and UL20 have specific guidelines that fire pump sets must meet. They are tested for performance and meet all necessary requirements. The Fire Pump Set must also have a factory-tested curve to ensure that it meets these requirements.
Drivers are an important component of any fire pump set. Drivers should be sized correctly to match the required horsepower of the pump. If you don't size the driver appropriately, the water pump may overflow its duty point and cause a fire. Make sure your driver is sized appropriately by consulting a certified factory test curve. This way, you can be assured that it's right for the job. This will prevent problems down the line.
A fire pump set is an integral part of a fire sprinkler system. Fire sprinklers are activated when the pressure in a fire sprinkler system drops below a certain level. The pump sets deliver water at high pressure to the fire suppression system. Fire pumps can also be used to supply water for underground water storage tanks. The pump set must be connected to an emergency generator or a separate generator to ensure proper operation during a power failure.
After installation, fire pumps must undergo regular preventive maintenance and annual operating tests to ensure that they are performing at their optimal level. Having a reliable pump system will protect your property from fire. To prevent future problems, you should perform regular visual inspections and hire a qualified fire management professional to conduct them. Then, you should be safe in the knowledge that your fire pump system is in top condition. So, take the time to read up on the various types of fire pump sets available.
Apart from pumps, you should consider a fire pump set's impeller shaft assembly. A fire pump's impeller shaft assembly is comprised of three parts: an intake section that surrounds the impeller, a volute that directs the water leaving the impeller, and an ejection port for the water to exit the pump. Each of these three components needs a clearance of a certain amount to be effective. The design of a fire pump set depends on its rated flow and pressure capacity.


EDJ Fire Pump System Electric Diesel Jockey Pump with Controller Fire Fighting Pump Set

  • DN Range of Suction Pipe: 50-400 mm (2"-16")
  • DN Range of Discharing Pipe: 32-350 mm (1.5"-14")
  • Flow Capacity Range: 50-5000 GPM
  • Head/Pressure Range: 4-14 Bar
  • Power Range: 4-325 Kw
 Chat Now  Inquiry Now  Add to My Favorite List  Download Catalog
  • The main pump can be end suction pump, multistage pump, split case pump,or vertical turbine pump with stainless steel, cast iron and bronze material in standard configurations.
  • Every package is mounted on a steel fabricated base with motor, engine and pump coupled and wired to the controller. The automatic air relief valve, gate valves, check valves, flexible joint, pressure switches, and pressure gauge are mounted on their respective pipes. If required, additional piping, pressure tank, valves and sensing lines are available as well.
  • Fire Pump Control Panel is the Pump System brain that designed to Control & Monitor the operation of the Electric, Diesel, and Jockey Pumps drivers, and makes up pumps for both Manual & Automatic modes, as well as turns pumps drivers ON/OFF under specific conditions.
    The Fire Pump Package Controller detects signals through set of built in pressure switches that reflect the system pressure & flow status enabling fire pump package drivers (Electrical /Diesel /Jockey) to operate in case of pressure in the system is lower than set point, as well as operating the Standby driver due to power failure and/or substantial drop in pressure.
    Fire Pumps Series Controllers are pre-wired, tested before delivery and made ready for immediate usage.
  • The electric pump is coupled with YE3 high efficient motor with protection IP55 class F, anti-corrosive coating pump case, quality NSK bearings, and wear resistance mechanical seal. Cast iron, brass and stainless steel impellers are all available.
  • This fire pump set can be used for fire hose and fire hose reel system, fire sprinkler system, fire water monitor system, fire alarm system and fire hydrant system.